Good engineering practice dictates your pumping station should, as a minimum:
- Include a chamber constructed of polypropylene, polyethylene or glass reinforced plastic (GRP).
- Have internal pipework made of steel, ABS plastic or Hi-Impact PVC (not uPVC).
- Incorporate a non-return valve.
- Have an anchoring method to prevent floatation.
Your Pumptec Packaged Pumping Station has all of the above and utilises rigid one-piece tanks across the range.
This makes them a commercially beneficial alternative to installing an adoptable scheme with many of the features available over and above the standard PPS specification, such as:
- Separate polyethylene valve chamber.
- Heavy-duty access covers.
- Integral over-pumping facility.
- Multi-compartment control panel.
- Ultrasonic level control in lieu of floatswitches.
- Telemetry/dial-out alarms.
- Remote monitoring of wastewater lift stations.
In addition virtually any make or type of submersible pump can be fitted into your Pumptec Packaged Pumping Station. So, if your preference is for Caprari, Flygt, ABS, KSB, Hydrostal, Robot, Grundfos, or whatever, it can be accommodated.
Similarly single and double channel, vortex or macerator pumps will be supplied dependent on application parameters and site requirements.
The Pumptec PPS Range consists of a single pump sump and backup pump systems as follows:
General Specifications
1211 SERIES
![]() | Tank Dimensions: | 1.25m diameter x 1.0m deep |
| Output: | 3 litres/second max | |
| Storage | 1000 litres max | |
| Minimum Volume: | 130 litres | |
| Pumps: | Single | |
| Inlet | 110 sockets x 2 max | |
| Outlet: | 63mm diameter max |
1216 SERIES
![]() | Tank Dimensions: | 1.25m diameter x 1.6m deep |
| Output: | 5 litres/second max | |
| Storage | 1700 litres max | |
| Minimum Volume: | 130 litres | |
| Pumps: | Single/twin | |
| Inlet | 110 sockets x 2 max | |
| Outlet: | 63mm diameter max |
1518 SERIES
![]() | Tank Dimensions: | 1.5m diameter x 1.8m deep |
| Output: | 10 litres/second max | |
| Storage | 3000 litres max | |
| Minimum Volume: | 800 litres | |
| Pumps: | Twin | |
| Inlet | 160 sockets x 2 max | |
| Outlet: | 110mm diameter max |
2000 SERIES
![]() | Tank Dimensions: | 2.0m diameter up to 3.0m deep |
| Output: | 75 litres/second max | |
| Storage | 9000 litres max | |
| Minimum Volume: | 1500 litres | |
| Pumps: | Twin | |
| Inlet | 200mm diameter x 2 max | |
| Outlet: | 160mm diameter max |